W1209 Thermostat Temperature Control Switch

Br 1,250.00

  • Temperature Control Range: -50 to 110 degree
  • Input Power: DC 12V
  • Resolution: -9.9 to 99.9 is 0.1 degree, other temperature ranges 1 degree
  • Measuring Inputs: NTC (10K 0.5%) Waterproof sensor
  • Measurement Accuracy: 0.1 degree
  • Output Range: 1 channel relay output, capacity is 10A
  • Control Accuracy: 0.1 degree
  • Environmental Requirements: -10-60 degree, humidity 20% -85%
  • Hysteresis Accuracy: 0.1 degree
  • Size: 48 x 40mm
  • Refresh rate: 0.5 Seconds
  • Power Consumption: Static Current: less than or equal to 35mA, attract current: less than or equal to 65mA
  • Temperature Protection: 0-110 degree
  • Display Type: 0.28″ three digital display tube

Out of stock

  • High Precision -50 – 110 Degree Heating And Cooling Thermostat Temperature Control Switch
  • W1209 is an intelligent thermostat sensor module, which has an onboard microcontroller chip and does not require any programming to function.
  • The W1209 comes with a high-precision NTC temperature sensor to sense the temperature around. The module has 3 tactile switches which help us customize the module’s parameters according to our needs.
  • The temperature sensor which is provided separately connects to the white connector. The module requires 12V to operate, so the 12V and the ground could be connected to an external power supply unit. The on-board relay can switch loads up to 240V AC at 5A and 12V DC at 10 A.
  • The module has various switches ‘SET’, ‘ ’, ‘-’ which can be used to display and set certain parameters of the thermostat sensor module.
  • By default, the display just shows the temperature values. If clicked set or any other button to vary the parameters, the module returns back to displaying the current temperature on the display after 5 seconds of inactivity.

Setting the trigger temperature

  • Trigger temperature refers to the temperature point when the relay switches ON/OFF. To set the trigger temperature, you have to press the SET button on the module. You can use the ‘ ’ and ‘-’ buttons to set the temperature by an increment and decrement of 0.1 Degrees. Once you have set the desired value, do not press any button and the value would be stored after 2 seconds automatically.

Setting the parameters(P0, P1, P2, P3, P4, P5, P6)

  • The module has seven parameters to set, which makes the module flexible for different applications. Setting a parameter on the module is done using the switches on the module only. To set any parameter, long-press the SET button for around 5 seconds. After 5 seconds, the module displays P0, the ‘ ’ and ‘-” buttons can be used to scroll through the different parameters(P0 to P6). Once you decide which parameter to be changed, go to that parameter using ‘ ’ and ‘-” buttons and press the set button once. Once you are in the specific parameter, you can change the values using the ‘ ’ and ‘-” buttons. After no activity for 5 seconds, the values will be set automatically and the module will return displaying its default temperature.

1. Heating or Cooling Parameter (P0):

  • The first parameter P0 has two settings, Cooling or Heating. It can be set based upon the application in which it has to be used(i.e. For heaters/coolers). While connecting a cooling system, set the P0 to ‘C’, as the relay will energize when the temperature is reached. Whereas, when using a heating system, set the P0 to ‘H’, as the relay will de-energize when the set temperature is reached.

2. Backlash/Hysteresis Parameter (P1):

  • This parameter can be used to prevent continual triggers whenever the temperature is around the set temperature. Or to say, the desired change in the temperature before relay actuation. If P1 is set to the default value of 2 Degrees C and the trigger temperature is 30 Degree C, the relay will only de-energize once it reaches around 28 Degrees C and not 30 Degree C.

3. Upper limit of the thermostat module (P2):

  • This parameter can be used as a safety measure. It sets up an upper limit for the user to set the high-temperature trigger value.

4. Lower limit of the thermostat module (P3):

  • This parameter can be used as a safety measure. It sets up a lower limit for the user to set the low-temperature trigger value.

5. Temperature Offset Correction Parameter (P4):

  • You can set an offset value if the temperature sensor is unable to display the exact value as the real temperature. If there is a difference in the displayed data and the actual data, an offset value can be set from a range of -7 to 7.

6. Trigger Delay Parameter (P5):

  • The P5 parameter can be used to provide a delay in relay actuation when the trigger temperature has been achieved. The delay in this parameter can be set up to 10 minutes.

7. Temperature Alarm Parameter (P6):

  • The parameter P6 is used as a safety feature. The relay switches off when the value set is reached. The on board display also shows a ‘—’ to indicate an alarming condition. It can be set to ‘OFF’ as default.