  • Set the temperature—-SetT;
  • Back temperature—–back;
  • Heating mode ‘�H� :

When temperature ≤ sett-backt; Relay driving, the heating equipment starts to work;

When the temperature ≥ SetT, relay disconnection, the heating equipment stops working;

  • Cooling mode ‘�C� :

When temperature ≥ SetT BackT; Relay driving, the refrigeration equipment starts to work;

When temperature ≤ SetT; Relay driving, the refrigeration equipment stops working;.

  • High Temperature Alarm ‘ ALA� :

When the temperature ≥ the alarm temperature, the system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;

  • OPH start delay :

When normal heating or cooling work is done, the system starts at time T, and only after t≥ Oph, the system can do the next round of heating or cooling work;

  • Temperature correction functionOFE (-10.0~10.0°):

The system will work for a long time and may have deviations that can be corrected by this function, temperature = measurement calibration;

  • Remote parameter reading/setting:

Parameters such as temperature setting, back tab temperature and temperature correction can be set via UART.

  • Real time temperature report:

If the temperature report function is turned on, the product is sent to the terminal by the UART at intervals of 1s, which facilitates data collection;

  • Relay activation (default activation):

If the relay is off, the relay remains off;

  • Factory reset:

At the same time press STOP, set the key more than 3S, restore factory settings;

Out of stock

  • Digital Heating Cooling Thermostat Temperature Control Switch Temperature Controller Module XY-T01

Working mode/back temperature setting:

  1. In the operation interface, short pressSet Enter the quick setup interface;
  2. After entering the quick setting interface, change the parameters.
  3. Through the up down key, modify the parameter value, support short press/long press;.
  4. Long pressSet To build more than 3S or 6S continuous without any key operation, exit quickly configure the interface and save the parameters;

Temperature alarm/start delay/temperature correction:

  1. In the operation interface, long pressSet More than 3s, enter the parameters to set the interface;
  2. Enter the parameter to set the interface, through the short pressSet key to switch to set the parameters;
  3. Through theUp down key, modify parameter value, support short press/long press;.
  4. Long pressSet above 3s or continuous 6s without any key operation, exit the parameter setting interface and save the parameters;

How to turn on the high temperature alarm (off by default):

  • Enter the parameter setting interface, switch to the alarm parameterALA , Turn on or off the high temperature alarm function by short pressing thestop button, and if the high temperature alarm function closes,ALA Displays ‘—-‘ as a reminder;

How to turn on the start delay (0ff by default):

  • Enter parameter setting interface, switch to alarm parameterOPH , Turn on or off the high temperature alarm function by short pressingstop button, if the high temperature alarm function closes,OPH Display ‘—-‘ to remind;

serial monitoring(�MCU UART)

  • Communication standards: 9600bps Data bits : 8
  • S Upper bits: 1
  • C RC : None
  • Flow control : None
  • temperature setting: -50 ~ -01, 00.0 ~ 99.9, 100 ~ 110