XY-T01 Temperature Controller
Br 1,250.00
- Set the temperature—-SetT;
- Back temperature—–back;
- Heating mode ‘�H�‘ :
When temperature ≤ sett-backt; Relay driving, the heating equipment starts to work;
When the temperature ≥ SetT, relay disconnection, the heating equipment stops working;
- Cooling mode ‘�C�‘ :
When temperature ≥ SetT BackT; Relay driving, the refrigeration equipment starts to work;
When temperature ≤ SetT; Relay driving, the refrigeration equipment stops working;.
- High Temperature Alarm ‘ ALA�‘ :
When the temperature ≥ the alarm temperature, the system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;
- OPH start delay‘ :
When normal heating or cooling work is done, the system starts at time T, and only after t≥ Oph, the system can do the next round of heating or cooling work;
- Temperature correction functionOFE (-10.0~10.0°):
The system will work for a long time and may have deviations that can be corrected by this function, temperature = measurement calibration;
- Remote parameter reading/setting:
Parameters such as temperature setting, back tab temperature and temperature correction can be set via UART.
- Real time temperature report:
If the temperature report function is turned on, the product is sent to the terminal by the UART at intervals of 1s, which facilitates data collection;
- Relay activation (default activation):
If the relay is off, the relay remains off;
- Factory reset:
At the same time press STOP, set the key more than 3S, restore factory settings;
Out of stock
- Digital Heating Cooling Thermostat Temperature Control Switch Temperature Controller Module XY-T01
Working mode/back temperature setting:
- In the operation interface, short pressSet Enter the quick setup interface;
- After entering the quick setting interface, change the parameters.
- Through the up down key, modify the parameter value, support short press/long press;.
- Long pressSet To build more than 3S or 6S continuous without any key operation, exit quickly configure the interface and save the parameters;
Temperature alarm/start delay/temperature correction:
- In the operation interface, long pressSet More than 3s, enter the parameters to set the interface;
- Enter the parameter to set the interface, through the short pressSet key to switch to set the parameters;
- Through theUp down key, modify parameter value, support short press/long press;.
- Long pressSet above 3s or continuous 6s without any key operation, exit the parameter setting interface and save the parameters;
How to turn on the high temperature alarm (off by default):
- Enter the parameter setting interface, switch to the alarm parameterALA , Turn on or off the high temperature alarm function by short pressing thestop button, and if the high temperature alarm function closes,ALA Displays ‘—-‘ as a reminder;
How to turn on the start delay (0ff by default):
- Enter parameter setting interface, switch to alarm parameterOPH , Turn on or off the high temperature alarm function by short pressingstop button, if the high temperature alarm function closes,OPH Display ‘—-‘ to remind;
serial monitoring(�MCU UART)
- Communication standards: 9600bps Data bits : 8
- S Upper bits: 1
- C RC : None
- Flow control : None
- temperature setting: -50 ~ -01, 00.0 ~ 99.9, 100 ~ 110