+251 99 380 2995 | +251 97 022 2227 | [email protected]
Temperature Controller YYW-2 0-1024℃
Br 3,500.00
- YYW-2 0-1024℃ Temperature Sensor Temperature Control Relay Detection High Temperature Serial Output with K Type Thermocouple 30A
- Input supply voltage: DC 7 ~ 30V universal
- Output controllable power: DC / AC within 30A
- Probe model: K-type thermocouple Wire length 0.5M
- Resolution: 1 degree
- Add ms level delay time to prevent output oscillation and cause damage to the entire circuit.
- Can turn off the display for a long time, reducing power consumption
- Synchronous data acquisition serial output
- Screw head specifications: M6
Function Description:
(A and B are the values we can set by ourselves)
- P–1: When the measurement is lower than the temperature value A, the relay is activated, and when the temperature is higher than the temperature value B, the relay is disconnected;
- P–2: When the measurement is higher than the temperature value B, the relay is activated, and when the temperature is lower than the temperature value A, the relay is disconnected;
- P–3: When the measured temperature is between A and B, the relay is turned off, and the relay is closed in other cases;
- P–4: When the measured temperature is between A and B, the relay is closed, otherwise the relay is opened;
- P–5: When the measured temperature is higher than the temperature value B, the relay is turned on, and the temperature is lower than the A relay is turned off;
- P–6: When the measured temperature is higher than the temperature value A, the relay is activated; it is always activated; until the power is cut off manually
- P–7: When the measured temperature is equal to A each time, the relay outputs a jog signal
Setting instructions:
Power-on indicates that the measured temperature enters the standby state;
- Press K1 for the first time (it takes more than 1 second to be effective to prevent false triggering), the screen flashes: P –1: K2 plus mode, K3 minus mode
- Press K1 a second time, the screen flashes: A025 means: A = 25 degrees: K2 and K3 adjust A
- Press K1 a third time, the screen flashes: B035 indicates: B = 35 degrees: K2 and K3 adjust B
- Press K1 for the fourth time, the display shows the measured real-time temperature indicating that it has entered the standby state;
- Press K4 in standby mode to permanently turn off / on the display and switch the low power consumption mode.
- YYW-2 0-1024℃ Temperature Sensor Temperature Control Relay Detection High Temperature Serial Output with K Type Thermocouple 30A
Package includes
- 1 x YYW-2 0-1024 ℃ Temperature Sensor Module
- 1 x K Type Thermocouple Sensor Cable